CVE-2026-109122

The network management service on affected Kiloview E3 NDI encoder firmware fails to sanitize one field used when configuring static routes via the web management API. An authenticated web user with permission to configure static routes can exploit this to execute arbitrary operating system commands as root, and the malicious configuration persists across reboots.

All CVEs
CVE-2026-109122Published 10/22/2026

The network management service on affected Kiloview E3 NDI encoder firmware fails to sanitize one field used when configuring static routes via the web management API. An authenticated web user with permission to configure static routes can exploit this to execute arbitrary operating system commands as root, and the malicious configuration persists across reboots.

Vendor advisory
CVSS9.4Critical

Overview

The network management service on affected Kiloview E3 NDI encoder firmware fails to sanitize one field used when configuring static routes via the web management API. An authenticated web user with permission to configure static routes can exploit this to execute arbitrary operating system commands as root, and the malicious configuration persists across reboots. Successful exploitation could result in full device compromise, including exposure of stored credentials and cryptographic material.

Published
10/22/2026
Last modified
10/23/2026
Assigned by
Not available
NVD analysis
Not available

Exploitation

No CISA KEV flag in the saved record

An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.

EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare

Affected products

Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.

Vendor / productAffected versionsPlatform / conditionsEvidence
E3 Firmware
Kiloview
< 1.30

Verify advisory

Source

Recommended actions

Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.

Vendor advisory links

Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.

Severity

CVSS describes technical impact. It is separate from exploitation evidence.

Published headline score: 9.4. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.

Sources & references

Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.