CVE-2026-32657

Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.

All CVEs
CVE-2026-32657Published 8/18/2026

Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.

Vendor advisory
CVSS7.3High

Overview

Dell AppSync Version 4.6.0.0, Dell Metro Node Version 8.0.0, Dell UCC Edge Version 3.0.1, Dell VxRail Version 8.0.322, Dell PowerMax Version 10.3.0, Dell Unity Version 5.4, Dell PowerFlex Manager Version 4.5.4, Dell PowerFlex Intelligent Catalog Versions 46.377.00 and 46.382.00 and Dell PowerFlex Rack version 4.5.4 and prior versions, contain(s) an UNIX Symbolic Link (Symlink) Following vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Published
8/18/2026
Last modified
8/20/2026
Assigned by
Not available
NVD analysis
Not available

Exploitation

No CISA KEV flag in the saved record

An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.

EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare

Affected products

Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.

Vendor / productAffected versionsPlatform / conditionsEvidence
AppSync
Dell
< 4.6.0.4 or later

Verify advisory

Source
Metro Node
Dell
< 4.6.0.4 or later

Verify advisory

Source
UCC Edge
Dell
< 3.0.2 or later

Verify advisory

Source
VxRail
Dell
< 8.0.330 or later

Verify advisory

Source
PowerMax
Dell
< 10.3.1.0 Patch 11248 or later

Verify advisory

Source
Unity
Dell
< 5.5.2 or later

Verify advisory

Source
PowerFlex Manager
Dell
< 4.5.5 or later

Verify advisory

Source
PowerFlex Intelligent Catalog
Dell
< 48.383.00 or later

Verify advisory

Source
PowerFlex Intelligent Catalog
Dell
< 48.378.00 or later

Verify advisory

Source
PowerFlex Rack
Dell
< 4.5.5 or later

Verify advisory

Source

Recommended actions

Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.

Vendor advisory links

Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.

Severity

CVSS describes technical impact. It is separate from exploitation evidence.

Published headline score: 7.3. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.

Sources & references

Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.