Skip to main content
Network Thinking Solutions Logo

CVE-2026-42804

A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI360 SensorAPI(C-Library) in versions up to and including commit d6b200416a.

All CVEs
CVE-2026-42804Published 9/10/2026

A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI360 SensorAPI(C-Library) in versions up to and including commit d6b200416a.

Vendor advisory
CVSS7.6High

Overview

A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI360 SensorAPI(C-Library) in versions up to and including commit d6b200416a. The vulnerability is located within the FIFO parsing and debug logging subsystem inside the function bhi360_parse_debug_message() in bhi360_parse.c (lines 1852-1875). The parser trusts the first payload byte of a debug frame as the message length (msg_length) and copies that many bytes into a fixed-size 17-byte stack buffer (debug_msg) via memcpy without performing any bounds checking. A locally or physically positioned attacker (e.g., via a malicious sensor, counterfeit hardware module, or a Man-in-the-Middle on the communication bus) can exploit this vulnerability by injecting a crafted debug frame with a length byte exceeding 16. This corrupts adjacent stack data, including the saved return address. Furthermore, because the overflowed buffer is subsequently passed to a printf-style logging sink, the attacker can supply format string specifiers (e.g., %n) to execute arbitrary code on the host microcontroller/SoC or cause a reliable system crash (Denial of Service).

Published
9/10/2026
Last modified
9/10/2026
Assigned by
Not available
NVD analysis
Not available

Exploitation

No CISA KEV flag in the saved record

An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.

EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare

Affected products

Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.

Vendor / productAffected versionsPlatform / conditionsEvidence
BHI360_SensorAPI (C-Library)
Bosch Sensortec
≥ 2.1.0, ≤ 2.2.0

Verify advisory

Source

Recommended actions

Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.

Vendor advisory links

Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.

Severity

CVSS describes technical impact. It is separate from exploitation evidence.

Published headline score: 7.6. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.

Sources & references

Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.