authd prior to version 0.6.4 contains a logic error in primary group ID assignment that can lead to local privilege escalation. When a user's primary group ID (GID) differs from their UID, either because the account was created with authd prior to version 0.
Overview
authd prior to version 0.6.4 contains a logic error in primary group ID assignment that can lead to local privilege escalation. When a user's primary group ID (GID) differs from their UID, either because the account was created with authd prior to version 0.5.4 or because the primary group was manually changed via the `authctl group set-gid` command, and the user's identity provider record is updated, authd incorrectly resets the user's primary group ID to their UID upon next login. This causes newly created files and directories to be owned by the wrong group, causing denial of service issues, and potentially granting unintended access to other local users and allowing local privilege escalation.
- Published
- 4/27/2026
- Last modified
- 10/26/2026
- Assigned by
- Not available
- NVD analysis
- Not available
Exploitation
No CISA KEV flag in the saved record
An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.
EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare
Affected products
Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.
| Vendor / product | Affected versions | Platform / conditions | Evidence |
|---|---|---|---|
authd Canonical | ≥ 0.6.0, < 0.6.4 | Verify advisory Verify the advisory platform, edition, update channel, and any version exceptions. | Source |
authd Canonical | ≥ 0.6.1, < 0.6.1ubuntu0.1 | Verify advisory Verify the advisory platform, edition, update channel, and any version exceptions. | Source |
Recommended actions
Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.
Vendor advisory links
Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.
Severity
CVSS describes technical impact. It is separate from exploitation evidence.
Published headline score: 7.3. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.
Sources & references
Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.