Skip to main content
Network Thinking Solutions Logo

CVE-2026-75910

Incorrect privilege assignment in the ClickHouse connector deployment template in Amazon Athena Federated Query prior to v2026.17.1 could allow an authenticated remote user to read arbitrary AWS Secrets Manager secrets in the deploying account by poi…

All CVEs
CVE-2026-75910Published 8/20/2026

Incorrect privilege assignment in the ClickHouse connector deployment template in Amazon Athena Federated Query prior to v2026.17.1 could allow an authenticated remote user to read arbitrary AWS Secrets Manager secrets in the deploying account by poi…

Vendor advisory
CVSS7.1High

Overview

Incorrect privilege assignment in the ClickHouse connector deployment template in Amazon Athena Federated Query prior to v2026.17.1 could allow an authenticated remote user to read arbitrary AWS Secrets Manager secrets in the deploying account by pointing the connector's connection string at an unrelated secret and at a database endpoint under the user's control, causing the connector to transmit the secret to that endpoint. To remediate this issue, users should upgrade to aws-athena-query-federation connectors version v2026.17.1 or later and ensure that any forked or derivative code is patched to incorporate the new fixes. Alternatively, to remediate this issue, users should redeploy the connector with the current template and supply a non-empty SecretNamePrefix value.

Published
8/20/2026
Last modified
10/18/2026
Assigned by
Not available
NVD analysis
Not available

Exploitation

No CISA KEV flag in the saved record

An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.

EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare

Affected products

Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.

Vendor / productAffected versionsPlatform / conditionsEvidence
Athena Federated Query Clickhouse Connector deployment template
AWS
< 2026.17.1

Verify advisory

Source

Recommended actions

Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.

Vendor advisory links

Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.

Severity

CVSS describes technical impact. It is separate from exploitation evidence.

Published headline score: 7.1. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.

Sources & references