Skip to main content
Network Thinking Solutions Logo

CVE-2026-79697

A vulnerability was determined in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.

All CVEs
CVE-2026-79697Published 9/7/2026

A vulnerability was determined in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.

Vendor advisory
CVSS8.6High

Overview

A vulnerability was determined in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. This affects the function basicstation_apply of the component Basic Station Certificate-Deletion Handler. This manipulation of the argument act causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 1.2.4_20260821 is able to mitigate this issue. Upgrading the affected component is advised. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Published
9/7/2026
Last modified
9/8/2026
Assigned by
Not available
NVD analysis
Not available

Exploitation

No CISA KEV flag in the saved record

An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.

EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare

Affected products

Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.

Vendor / productAffected versionsPlatform / conditionsEvidence
WISE-6610-NB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-EB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-TB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-JB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-CB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-EL-NB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-EL-EB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-EL-TB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-EL-JB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610-EL-CB
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610P-DEA
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610P-DNA
Advantech
1.2.1_20251110

Verify advisory

Source
WISE-6610P-DTA
Advantech
1.2.1_20251110

Verify advisory

Source

Recommended actions

Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.

Vendor advisory links

Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.

Severity

CVSS describes technical impact. It is separate from exploitation evidence.

Published headline score: 8.6. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.

Sources & references

Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.