Nodemailer versions >= 6.9.16 and < 9.1.0 mis-parse RFC 5322 comments in email addresses: in lib/addressparser, a comment closed immediately before a non-break character causes the tokenizer to concatenate the atoms surrounding the comment instead of treating the comment as folding whitespace that terminates the domain.
Overview
Nodemailer versions >= 6.9.16 and < 9.1.0 mis-parse RFC 5322 comments in email addresses: in lib/addressparser, a comment closed immediately before a non-break character causes the tokenizer to concatenate the atoms surrounding the comment instead of treating the comment as folding whitespace that terminates the domain. A recipient address such as user@good-corp.com(x)evil.com is therefore read by Nodemailer as the single domain good-corp.comevil.com (registrable domain comevil.com, which an attacker can register) and used for both the SMTP envelope (RCPT TO) and the emitted To:/From: headers, while a conformant RFC 5322 parser terminates the domain at the comment and reads good-corp.com. An application that validates the recipient domain with a strict RFC 5322 parser (without inspecting parse defects) or a naive prefix/substring allow-list and then hands the raw address to Nodemailer can be induced to deliver mail to a domain the attacker controls. Fixed in 9.1.0.
- Published
- 9/16/2026
- Last modified
- 9/22/2026
- Assigned by
- Not available
- NVD analysis
- Not available
Exploitation
No CISA KEV flag in the saved record
An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.
EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare
Affected products
Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.
| Vendor / product | Affected versions | Platform / conditions | Evidence |
|---|---|---|---|
nodemailer nodemailer | ≥ 6.9.16, < 9.1.0 | Verify advisory | Source |
Recommended actions
Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.
Vendor advisory links
Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.
Severity
CVSS describes technical impact. It is separate from exploitation evidence.
Published headline score: 8.3. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.
Sources & references
Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.