Skip to main content
Network Thinking Solutions Logo

CVE-2026-9651

CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.

All CVEs
CVE-2026-9651Published 6/25/2026

CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.

Vendor advisory
CVSS6.7Medium

Overview

CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.

Published
6/25/2026
Last modified
7/14/2026
Assigned by
Not available
NVD analysis
Not available

Exploitation

No CISA KEV flag in the saved record

An absent KEV flag does not establish that exploitation has never occurred. Verify current intelligence before prioritizing work.

EPSS predictions and CISA SSVC assessments are not imported here. Review additional intelligence on Cloudflare

Affected products

Affected-version rules published in the advisory. Conditions and uncertain comparisons require verification.

Vendor / productAffected versionsPlatform / conditionsEvidence
easylogic t150 firmware
schneider-electric
< 11.06.32

Verify advisory

The advisory has platform, edition, hardware, or configuration conditions not verified by software inventory.

Source
saitel dp firmware
schneider-electric
< 11.06.38

Verify advisory

The advisory has platform, edition, hardware, or configuration conditions not verified by software inventory.

Source
EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller
Schneider Electric
Version 11.06.31 and prior

Verify advisory

Source
Saitel DP Remote Terminal Unit & Controller
Schneider Electric
Version 11.06.37 and prior

Verify advisory

Source

Recommended actions

Verify the product, installed version, platform, and advisory prerequisites on each system. Apply the vendor's applicable fixed release or mitigation. An affected-range boundary alone is not a universal update recommendation.

Vendor advisory links

Derived from non-aggregator references because the source record has no vendor tags. Verify the advisory before acting on it.

Severity

CVSS describes technical impact. It is separate from exploitation evidence.

Published headline score: 6.7. Score version, vector, and attribution are not available in this record. Additional score details appear when the source record is next refreshed.

Sources & references

Sources: Official CVE List, NVD and cve.now (summaries CC BY 4.0). Uses NVD data; not endorsed by NVD.